Baseline model fit on 5 months
before Jul 2023; savings measured over the
5 reporting months after it.
This is synthetic demo data with no efficiency intervention, so
avoided energy should read near 0% — that's the method working
correctly. On real post-retrofit data, this is where a program's verified savings appear.
Avoided energy
-6.7%
-6785 kWh / meter
Adjusted baseline (CBL)
101846
kWh / meter expected
Reporting actual
108631
kWh / meter metered
Baseline fit (R²)
0.847
degree-day model
Reporting period: actual vs. adjusted baseline
kWh / meter · monthBars are metered use; the line is the weather-adjusted baseline (CBL). The gap between them, summed over the reporting period, is the avoided energy.
The baseline model
E = 17570 + -3.8478·HDD + 9.7073·CDD
- Heating slope: -3.8478 / HDD
- Cooling slope: 9.7073 / CDD
- Avoided: -6785 kWh/meter (-6.7%)
Method: IPMVP Option C (EVO 10000-1:2016);
weather-adjusted baseline per ASHRAE Guideline 14; base-65°F degree days (US EIA / NOAA).