Guided tour
Sample data · no sign-up
Baseline vs. reporting
Baseline model fit on 5 months
before Jul 2023; savings measured over the
6 reporting months after it.
This is synthetic demo data with no efficiency intervention, so
avoided energy should read near 0% — that's the method working
correctly. On real post-retrofit data, this is where a program's verified savings appear.
Avoided energy
-1.3%
-549 kWh / meter
Adjusted baseline (CBL)
41891
kWh / meter expected
Reporting actual
42440
kWh / meter metered
Baseline fit (R²)
0.953
degree-day model
Reporting period: actual vs. adjusted baseline
kWh / meter · monthBars are metered use; the line is the weather-adjusted baseline (CBL). The gap between them, summed over the reporting period, is the avoided energy.
The baseline model
E = 7225 + -4.7697·HDD + 1.8199·CDD
- Heating slope: -4.7697 / HDD
- Cooling slope: 1.8199 / CDD
- Avoided: -549 kWh/meter (-1.3%)
Method: IPMVP Option C (EVO 10000-1:2016);
weather-adjusted baseline per ASHRAE Guideline 14; base-65°F degree days (US EIA / NOAA).