All demo datasets

Gas — Rural Co-op

Prairie Gas Co-op (synthetic)
Guided tour Sample data · no sign-up
UnitTrack · Disclosure-controlled report

Gas — Rural Co-op

Prairie Gas Co-op (synthetic)
Generated 2026-07-27 19:41 · Grouped by customer class · k = 15
Residual re-identification risk
worst case 1% · Low · smallest published group 100
1/3
Customer class groups published
of meter reads in published output
2
groups withheld by disclosure control
15/15 rule
≥15 contributors; no single customer over 15%
Contents
  1. Disclosure control & data provenance
  2. Consumption profile
  3. Weather & seasonality
  4. Benchmarking (EUI)
  5. Energy burden & equity
  6. Measurement & verification (M&V)
  7. Differential privacy (alternative release)
  8. Appendix — policy & citations

Disclosure control & data provenance

Grouping the dataset into 3 customer class groups, 1 were safe to publish and 2 were withheld under the rules below. The exact share published and the grand total are withheld here so the small suppressed group can't be recovered by subtraction; the published output carries a worst-case re-identification risk of 1% (Low).

Data quality & reliability
1440
Loaded reads
0 rejected & quarantined
4.4%
Estimated reads
utility estimate flag
0.3%
Negative usage
rollovers / net metering
206
High outliers
Tukey 1.5·IQR (1977)

Anomalies are flagged, not dropped; rows failing validation are quarantined as rejected. 24 reads (1.7%) lack coordinates and are excluded from spatial views.

Methods & authorities
  • Minimum-count (k-anonymity) — 1 group withheld (triggered by your minimum group size k = 15).
    Sweeney, k-anonymity (2002); ESSnet/Eurostat SDC Handbook (Hundepool et al.) — minimum-frequency / threshold rule · Meets/exceeds: CA CPUC D.14-05-016 ("15/15"); IL 220 ILCS 33
  • (n,k)-dominance — 1 group withheld (triggered by your top-1 dominance limit p = 15%).
    ESSnet/Eurostat SDC Handbook §4.2 (Hundepool et al.) — sensitive cells in magnitude tables
  • PII handling — identifiers are excluded from the analytic path; only disclosure-controlled aggregates are reported.
    NIST SP 800-122; NISTIR 8053
Published results
Customer class Total consumption (therms) Contributors Status
INDUSTRIAL * Withheld
COMMERCIAL * Withheld
RESIDENTIAL 153,364 100 Published
Explore live →

Consumption profile

Total consumption by customer class — published groups (therms)
Consumption distribution & inequality
0.927
Gini coefficient
Gini 1912; Lorenz 1905
6.954
Coefficient of variation
std ÷ mean
1509
Median use / account (therms/yr)
across 120 accounts
19
High outliers
Tukey 1.5·IQR
Lorenz curve — cumulative use vs. cumulative accounts
Percentiles (therms/yr)
10thwithheld
25th968
Median1509
75th2802
90thwithheld
Outer percentiles withheld (tail-coding; ESSnet SDC Handbook; NIST SP 800-188).
Customer class × month
Total consumption — class (rows) × month (columns); blanks were suppressed (therms)
Explore distribution live →

Weather & seasonality

38.2%
Weather-sensitive (heating-driven)
ASHRAE G14; PRISM
100.0% / 0.0%
Heating / cooling split
of weather-driven use
Weather-normalized annual
restated at normal year
0.587
Model fit (R²)
degree-day regression

E = 1353 + 4.1457·HDD  ·  base 65°F · 11 months

Seasonal use — 71.8% above winter baseline, peak Apr
Average monthly consumption vs. winter baseline (therms)
Winter-baseline (minimum-month) method. Standard seasonal decomposition.
Explore weather live →

Benchmarking — Energy Use Intensity

71.0
Median EUI (kBtu/ft²/yr)
EPA ENERGY STAR; DOE/EIA CBECS
115
Buildings benchmarked
floor area & ≥ 2 months
1 kWh = 3.412 kBtu; 1 therm = 100 kBtu (EIA)
reference constants v2024.1
EUI distribution across buildings (published classes)
By customer class (site EUI, kBtu/ft²/yr)
ClassBldgsp25Medianp75vs nat'l
RESIDENTIAL 100 43.169.7113.1 232%
COMMERCIAL 15 32.477.1199.5 110%
INDUSTRIAL 5 ****
Within-dataset EUI percentiles vs. class peers. “vs nat'l” is coarse all-fuel context (CBECS 2018 / RECS 2020), not the ENERGY STAR 1–100 score. Small classes withheld.
Explore benchmarking live →

Energy burden & equity

Every census tract was suppressed — no tract had at least 15 accounts with an ACS median income on record.

Explore burden live →

Measurement & verification (IPMVP Option C)

Baseline model fit on 5 months before Jul 2023; savings measured over the following 6 reporting months. Synthetic demo with no intervention — avoided energy near 0% is the method working correctly.

13.2%
Avoided energy
1377 therms/meter
10399
Adjusted baseline (CBL)
therms/meter expected
9022
Reporting actual
therms/meter metered
0.613
Baseline fit (R²)
degree-day model
Reporting period: metered actual vs. adjusted baseline (therms/meter)
IPMVP Option C (EVO 10000-1:2016); ASHRAE Guideline 14; base-65°F degree days (US EIA / NOAA).
Explore M&V live →

Differential privacy — an alternative release

An alternative to suppression: instead of hiding small groups, calibrated Laplace noise is added to each count (ε = 1.0, scale b = 1.0) so no individual's presence can be inferred while totals stay useful. Mean absolute error ±0.7 across 3 groups.

True vs. differentially private counts by customer class
Laplace mechanism, ε-differential privacy. Dwork, McSherry, Nissim & Smith (2006); Dwork & Roth (2014); US Census Bureau 2020 DAS.
Explore differential privacy live →

Appendix — policy & citations

Disclosure-control settings
Governing standard15/15 rule
Minimum group size (k)15
Dominance (top-n ≤ p)1 ≤ 0.15
Min accounts for models15
GroupingCustomer class
Standards & sources cited
  • k-anonymity — Sweeney (2002); ESSnet/Eurostat SDC Handbook
  • (n,k)-dominance — ESSnet SDC Handbook §4.2; CPUC 15/15
  • Inequality — Gini (1912); Lorenz (1905)
  • Spatial — Moran (1950); Cliff & Ord (1973)
  • Weather / M&V — ASHRAE Guideline 14; IPMVP Option C; PRISM
  • Benchmarking — EPA ENERGY STAR; DOE/EIA CBECS/RECS
  • Load — NREL UMP; BPA M&V Peak Demand
  • Burden — ACEEE; US Census ACS
  • Differential privacy — Dwork et al. (2006); US Census 2020 DAS
  • PII — NIST SP 800-122; NISTIR 8053; NIST SP 800-188
  • Methods & Formulas — every rule & analysis with its formula-as-implemented and primary citation

Synthetic sample data — for demonstration, not distribution. Generated by UnitTrack, a Polish Clover Solutions product · 2026-07-27 19:41.