Baseline vs. reporting Baseline model fit on 5 months before Jul 2023; savings measured over the 6 reporting months after it.
This is synthetic demo data with no efficiency intervention, so avoided energy should read near 0% — that's the method working correctly. On real post-retrofit data, this is where a program's verified savings appear.
Avoided energy
13.2%
1377 therms / meter
Adjusted baseline (CBL)
10399
therms / meter expected
Reporting actual
9022
therms / meter metered
Baseline fit (R²)
0.613
degree-day model

Reporting period: actual vs. adjusted baseline

therms / meter · month

Bars are metered use; the line is the weather-adjusted baseline (CBL). The gap between them, summed over the reporting period, is the avoided energy.

The baseline model

E = 3250 + 0.9114·HDD + -4.754·CDD

  • Heating slope: 0.9114 / HDD
  • Cooling slope: -4.754 / CDD
  • Avoided: 1377 therms/meter (13.2%)
Method: IPMVP Option C (EVO 10000-1:2016); weather-adjusted baseline per ASHRAE Guideline 14; base-65°F degree days (US EIA / NOAA).